SICO GCSLow-voltage Switch Cabinets/ Distribution Panels/Switchgear/Low Voltage Panels

SICO GCSLow-voltage Switch Cabinets/ Distribution Panels/Switchgear/Low Voltage Panels
Product Detailed
Related Categories:Power Distribution Equipment
switch cabinets Fixed Switchgear,Protective Control Cabinet 1.380,400,660V 2.ABB, Schneider, GE parts optional

Please contact Ms.Amy YIN --- yinamy9@gmail [dot] com and sikeqd@126 [dot] com

Fixed Switchgear,Protective Control Cabinet 1.380,400,660V 2.ABB, Schneider, GE parts optional 3.IEC439,GB7251 4.IP2X

 

GCS Type Low-Voltage Withdrawable Switchgear/ Swtichboard/ switch box

I. Range of Use & PurposeThe switch cabinet is applied to the distribution system in the power plants, high-rise buildings, chemical industry, and petroleum, metallurgy and textile industries. In the large power plants and highly automated petroleum and chemical industries that require connecting with computers, it is used, as a complete low-voltage distribution equipment, for power distribution in the power generation and distribution system with three-phase AC frequency 50(60)Hz, 380V(400)(600) and rated current up to and including 4000A, and motor centralized-control and reactive power compensation.

II Service condition

1. Ambient temperature: -15'C~+40'C

2. Altitude: <=1000m

3. Air humidity:

daily average of Air humidity <=95%, daily average of partial vapor pressure <= 2.2kPa;

monthly average of Air humidity <=90%, monthly average of partial vapor pressure <= 1.8kPa

4. Earthquake intensity <= 8 degree

5. No corrosive or flammable gas

Special condition subject to users

III. Basic Parameters

Rated voltage of main circuit (V)

AC 380(400)(660)

Rated voltage of ancillary circuit (V)

AC 220 380(400) DC 110 220

Rated frequency (Hz)

50(60)

Nominal insulation voltage (V)

660(1000)

Rated current (A)

Horizontal bus

≤4000

Vertical bus (MCC)

1000

Bus rated short-time withstand current (KV/1S)

50 80

Bus rated peak withstand current (KV/0.1S)

105 176

Degree of protection

IP3X IP4X

IV. Main StructureThe main structure adopts 8FM opening section steel, in both sides of which there are two mounting holes with modulus 20mm and 100mmφ9.2mm respectively. The internal mounting is flexible and convenient.The main structure has two alternatives of mode of assembly, i.e. fully assembled structure and the structure with welded part frames and beam.All the function chambers of the cabinet are separated. The compartments include a functional unit chamber, a bus chamber and a cable chamber. All the chambers are independent relatively.The horizontal main bus bar is arranged horizontally on the cabinet back for the purpose of enhancing the bus’s capability of resisting electromotive power. This is a basic measure to make the main circuit have a high short circuit withstand strength.The design of cable compartment enables the cables to pass through upwards or downwards to be extremely convenient.V. The universal dimensions (mm) of the cabinet are shown in the following table

Height

2200

Width

400

600

800

1000

Depth

800

1000

800

1000

600

800

1000

600

800

1000

VI. Functional UnitsThe course height of drawer is 160mm, including such five dimensions as 1/2 unit, 1 unit, unit, 2 units and 3 units. The rated current of unit circuit is up to and including 400A.The modification of drawer is generally made to the height but not to that of width and depth. The drawers with same fictional units are interchangeable.Each MCC cabinet is able to mount 11 1-unit or 22 1/2-unit at most.The incoming and outgoing lines of drawer adopt the chip structure socket connectors with different number of chips but same specification according to the current intensity.The drawers of 1/2 unit are switched to the cable chamber by means of the ZJ-2 type switch parts of back plate type structure.The unit drawer is switched to the cable chamber by means of bar or tubular ZJ-1 type switch parts of the same size according to the classification of current.There are obvious marks in the positions of separation, closing, test and drawing out in the drawer panel.The drawer unit is equipped with a mechanical interlocking device.VII. Ordering InstructionsThe purchase contract should cover the following items.The full series of product includes the numbers of main circuit scheme and ancillary circuit scheme.Diagram on the combination sequence of main circuit systemElectric schematic diagram of ancillary circuitList of components in cabinets Voltage, current and time and other adjustment variables in circuitOther special requirements differing from normal using of product

If you are interested in our MNS switch cabinets , please contact Miss YIN  sikeqd [at] 126 [dot ]com; yucixin [at] hotmail [dot] com. Thank you!

( function(){ var aBigImageSrc = [ 'http://i01.i.aliimg.com/photo/v3/616092351_1/SICO_GCSLow_voltage_Switch_Cabinets_Distribution_Panels.jpg' , 'http://i01.i.aliimg.com/photo/v3/616092351_2/SICO_GCSLow_voltage_Switch_Cabinets_Distribution_Panels.jpg' , 'http://i01.i.aliimg.com/photo/v3/616092351_3/SICO_GCSLow_voltage_Switch_Cabinets_Distribution_Panels.jpg' , 'http://i01.i.aliimg.com/photo/v3/616092351_4/SICO_GCSLow_voltage_Switch_Cabinets_Distribution_Panels.jpg' , 'http://i01.i.aliimg.com/photo/v3/616092351_5/SICO_GCSLow_voltage_Switch_Cabinets_Distribution_Panels.jpg' , 'http://i01.i.aliimg.com/photo/v3/616092351_6/SICO_GCSLow_voltage_Switch_Cabinets_Distribution_Panels.jpg' ]; var oProductShow = new AE.run.minisite.productShow(); oProductShow.init( { 'aImgSrc': aBigImageSrc } ); } )(); SICO GCSLow-voltage Switch Cabinets/ Distribution Panels/Switchgear/Low Voltage Panels